BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//NYSWDA | NYS Weatherization Directors Association - ECPv6.18.3.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:NYSWDA | NYS Weatherization Directors Association
X-ORIGINAL-URL:https://zealous-williams.67-222-27-37.plesk.page
X-WR-CALDESC:Events for NYSWDA | NYS Weatherization Directors Association
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20250309T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20251102T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20260308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20261101T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20270314T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20271107T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20261117T090000
DTEND;TZID=America/New_York:20261117T170000
DTSTAMP:20261111T140330Z
CREATED:20261111T140330Z
LAST-MODIFIED:20261111T140330Z
UID:10000028-1794906000-1794934800@zealous-williams.67-222-27-37.plesk.page
SUMMARY:BPI Cold Climate Air Source Heat Pump Assessor
DESCRIPTION:Training Location:  NYSWDA Training Center – 5869 Fisher Road\, East Syracuse\, NY  13057  \nWhat is the ccASHP? \nThe ccASHP Assessor Certificate of Knowledge demonstrates your ability to evaluate residential buildings for cold climate air source heat pump readiness and retrofit potential. This certificate verifies your knowledge of HVAC systems\, building envelopes\, and electrical capacity\, as well as your skills in assessing site feasibility\, equipment compatibility\, and occupant needs. It highlights your expertise in supporting efficient\, healthy\, and safe adoption of cold climate heat pump technology.   \nWhat You’ll Learn \n\nCold Climate Air Source Heat Pump (ccASHP) Fundamentals\nClient Needs and Priorities\nSite Feasibility and Constraints\nExisting HVAC and Distribution Assessments\nBuilding Envelope\nElectrical Service Overview\nEquipment Compatibility and Basic Controls\nRisk Communication and Mitigation\nEconomics\, Incentives\, and Carbon Impacts\nHealth and Safety\n\nPrerequisites: Prerequisites help potential test takers determine their readiness to challenge the exam. Pre-requisites include at least one of the following: \n\nBPI certification\nNATE Heat Pump (Service or Installation)\nRESNET HERS Rater or RFI\nHVAC Excellence Heat Pump (Employment Ready or Professional Technician)\nEnergy Skilled Heat Pump: Energy Skilled Heat Pump Programs | Building Science Education\nOr similar industry credentials\nAt least 1 year of technical trades instruction\, including HS-level vocational instruction\nAt least 1 year of work experience in a field directly related to heating and cooling systems\, such as HVAC installation\, maintenance\, energy auditing\, or building performance assessment.\nCandidates confirm their qualifications through a self-reporting checklist online before they take the exam. BPI conducts random audits to maintain program integrity.\n\nExam Information: \n\nThe open book multiple-choice exam consists of 75 scored multiple-choice questions. There is no time limit for the exam.\nThe exam passing score is 80%\nCandidates will receive classroom instruction followed by taking the open-book\, online exam in-house \n\n\nWho Should Attend;\nAnyone who is part of the energy efficiency and clean energy workforce and meets the prerequisites can take the ccASHP Assessor Certificate of Knowledge exam.  \nDates;\nNovember 17\, 2026 \nClass Size: 8  \nBPI CEU: 6 \nInstructors:\nDave Hill\, NYSWDA HVAC trainer \nCourse Fees; \n$300/person – NY Weatherization Sub-grantees \n$300/person – affiliate members \n$400/person – non-members  \nTraining fees include the online test \nAttendees are given a lunch break\, but lunch is not included in the training fees.\n \n**Special note – if you wish to become an Affiliate Member\, and save off the non-member rate\, please contact Karen McMahon (315-701-0440 ext. 223\, kmcmahon@nyswda.org) BEFORE YOU REGISTER for the course.
URL:https://zealous-williams.67-222-27-37.plesk.page/event/bpi-cold-climate-air-source-heat-pump-assessor/
LOCATION:NYSWDA Training Center\, 5869 Fisher Road\, East Syracuse\, NY\, 13057\, United States
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20261202T100000
DTEND;TZID=America/New_York:20261202T150000
DTSTAMP:20261111T140330Z
CREATED:20261111T140330Z
LAST-MODIFIED:20261111T140330Z
UID:10000031-1796205600-1796223600@zealous-williams.67-222-27-37.plesk.page
SUMMARY:Mitsubishi Electric M & P Series Product & Application
DESCRIPTION:Training Location:  NYSWDA Training Center – 5869 Fisher Road\, East Syracuse\, NY  13057  \nCourse Description:\nThis training provides a practical overview of Mitsubishi's M-Series and P-Series heat pump systems with a focus on proper equipment selection\, system design\, and application.  Participants will learn how to match products to residential and light commercial projects\, understand single-zoned and multi-zoned configurations\, apply Hyper-Heating technology\, select the right indoor and outdoor unit combinations\, and design systems for optimal comfort\, efficiency\, and performance.  The session also covers key installation considerations\, controls\, and best practices for successful project execution. \nThis Training Is Ideal For: \n\nHVAC Sales Professionals\n\nLearn how to position Mitsubishi's M-Series\, P-Series\, Hyper-Heat\, intelli-HEAT\, and Smart Multi solutions.\nUnderstand key differentiators\, efficiency ratings\, rebate opportunities\, and comfort features.\n\nHVAC System Designers & Comfort Advisors\n\nBest practices for equipment selection and application. Importance of Manual J\, Manual S.\nHyper-Heating performance\, dual-fuel applications\, Smart Multi design considerations\, and indoor unit selection.\n\nInstallation Technicians\n\nR-454B/A2L safety requirements.\nRefrigerant leak detection requirements\, sensor installations\, piping updates\, wiring changes\, startup considerations\, and commissioning best practices. ✅ Service Technicians\nNew controls\, diagnostic features\, leak detection systems\, refrigerant recovery functions\, error codes\, and troubleshooting updates for next-generation equipment.\n\nDistributor Counter & Inside Sales Teams\n\nProduct lineup updates\, nomenclature changes\, accessory selection\, compatibility requirements\, and application support knowledge.\n\nBusiness Owners & Managers\n\nPrepare your team for the industry's transition to low-GWP refrigerants and Mitsubishi's newest residential and light commercial product offerings.\n\n\nDate:\nDecember 2\, 2026  \nPrerequisites:None \nClass Size: 20\n \nBPI CEU: 4 \nInstructor:\nJohn Carrigan – Mitsubishi Electric Trane HVAC US LLC \nCourse Fees: \nNone  \nCLASS FULL – call or email  rwolk@nyswda.org for availability or wait list
URL:https://zealous-williams.67-222-27-37.plesk.page/event/mitsubishi-electric-m-p-series-product-application-2/
LOCATION:NYSWDA Training Center\, 5869 Fisher Road\, East Syracuse\, NY\, 13057\, United States
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20261208T100000
DTEND;TZID=America/New_York:20261208T150000
DTSTAMP:20261111T140330Z
CREATED:20261111T140330Z
LAST-MODIFIED:20261111T140330Z
UID:10000032-1796724000-1796742000@zealous-williams.67-222-27-37.plesk.page
SUMMARY:Mitsubishi Electric M & P Series Product & Application
DESCRIPTION:Training Location:  NYSWDA Training Center – 5869 Fisher Road\, East Syracuse\, NY  13057  \nCourse Description:\nThis training provides a practical overview of Mitsubishi's M-Series and P-Series heat pump systems with a focus on proper equipment selection\, system design\, and application.  Participants will learn how to match products to residential and light commercial projects\, understand single-zoned and multi-zoned configurations\, apply Hyper-Heating technology\, select the right indoor and outdoor unit combinations\, and design systems for optimal comfort\, efficiency\, and performance.  The session also covers key installation considerations\, controls\, and best practices for successful project execution. \nThis Training Is Ideal For: \n\nHVAC Sales Professionals\n\nLearn how to position Mitsubishi's M-Series\, P-Series\, Hyper-Heat\, intelli-HEAT\, and Smart Multi solutions.\nUnderstand key differentiators\, efficiency ratings\, rebate opportunities\, and comfort features.\n\nHVAC System Designers & Comfort Advisors\n\nBest practices for equipment selection and application. Importance of Manual J\, Manual S.\nHyper-Heating performance\, dual-fuel applications\, Smart Multi design considerations\, and indoor unit selection.\n\nInstallation Technicians\n\nR-454B/A2L safety requirements.\nRefrigerant leak detection requirements\, sensor installations\, piping updates\, wiring changes\, startup considerations\, and commissioning best practices. ✅ Service Technicians\nNew controls\, diagnostic features\, leak detection systems\, refrigerant recovery functions\, error codes\, and troubleshooting updates for next-generation equipment.\n\nDistributor Counter & Inside Sales Teams\n\nProduct lineup updates\, nomenclature changes\, accessory selection\, compatibility requirements\, and application support knowledge.\n\nBusiness Owners & Managers\n\nPrepare your team for the industry's transition to low-GWP refrigerants and Mitsubishi's newest residential and light commercial product offerings.\n\n\nDate:\nDecember 8\, 2026  \nPrerequisites:None \nClass Size: 20\n \nBPI CEU: 4 \nInstructor:\nJohn Carrigan – Mitsubishi Electric Trane HVAC US LLC \nCourse Fees: \nNone 
URL:https://zealous-williams.67-222-27-37.plesk.page/event/mitsubishi-electric-m-p-series-product-application/
LOCATION:NYSWDA Training Center\, 5869 Fisher Road\, East Syracuse\, NY\, 13057\, United States
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20261209T090000
DTEND;TZID=America/New_York:20261210T160000
DTSTAMP:20261111T140330Z
CREATED:20261111T140330Z
LAST-MODIFIED:20261111T140330Z
UID:10000033-1796806800-1796918400@zealous-williams.67-222-27-37.plesk.page
SUMMARY:HVAC Troubleshooting Techniques
DESCRIPTION:Training location:  NYSWDA Training Center – 5869 Fisher Road\, East Syracuse\, NY  13057 \nThis training is for:\nEXPERIENCED WAP heating technicians / HVAC technicians and contractors \nCourse Description:\nThis challenging 2-day course will teach the skills required to troubleshoot a furnace or boiler to the component level. Using a multimeter and unit schematics\, an HVAC technician will learn the skills necessary to quickly and accurately diagnose HVAC system problems. In NYSWDA's state-of-the-art HVAC lab\, trainees will troubleshoot computer-simulated HVAC circuits and controls and will diagnose up to 5 different furnaces\, all having had their controls rigged to fail under various conditions. As part of this training\, attendees will also learn electrical theory including OHM's Law\, series and parallel circuits\, wiring schematic interpretation\, and multimeter use. \nAgenda:\nDay One: Classroom\n \n\nElectrical theory\nHow to read wiring schematics\nSequence of operation\nTroubleshooting with multimeters\nComputer simulated troubleshooting\n\nDay Two: Classroom/ HVAC Lab\n \n\nComputer simulated troubleshooting\nHands-on lab troubleshooting skills \n\n\nDates;\nCourse covers the dates of December 9-10\, 2026 \n  \nPrerequisites:\nHVAC technician/contractor with basic knowledge of heating control circuits and components \n  \nClass Size: 6  \nBPI CEU: 16  \nInstructors:Dave Hill – HVAC instructor – NYSWDA  \nOther Notes:\nAttendees please bring your digital multimeter w/ spare batteries & flashlight \n  \nCourse Fees: \n$517/person – NY Weatherization Sub-grantees \n$517/person – affiliate members\n$750/person – non-members    \n**Special note – if you wish to become an Affiliate Member\, and save off the non-member rate\, please contact Karen McMahon (315-701-0440\, ext 223)\, kmcmahon@nyswda.org) BEFORE YOU REGISTER for the course.
URL:https://zealous-williams.67-222-27-37.plesk.page/event/hvac-troubleshooting-techniques/
LOCATION:NYSWDA Training Center\, 5869 Fisher Road\, East Syracuse\, NY\, 13057\, United States
END:VEVENT
END:VCALENDAR